    1. Welcome to our website! Company specializing in the production of a variety of fume hood, fume hood, laboratory furniture, laboratory equipment and ancillary equipment, customers are welcome to inquire. We will provide the best solution and the best service.
       
      Sales Hotline:0086-13961512632
       
            Product Series
             Fume Hood
             Test series
             Experimental Cabinet
             Test panel
             Clean Bench
             Laboratory gas pipeline
             Set exhaust equipment
             Waste water & Waste gas treatment equipment
             Primary and secondary school teaching equipment
             Laboratory equipment
             Stainless steel products
             Imported equipment
          Fume Hood
       
      Counter:21801  2007-3-21 下午 10:04:11

      Material description of all steel fume hood or fume hood

      A. structure: the three section combined type cabinet, the upper body (ventilation cabinet), middle (operation table), the lower cabinet (cabinet designed to accommodate independent exhaust type composition containing unilateral cabinet and the other side of the independent water and electricity, pipeline system.
      B. shell: the use of thick 1.2mm (including) above the steel plate stamping production, the surface of the acid and alkali resistant EPOXY powder coating treatment.
      C. inside the shell: the use of imported acid and alkali fume hood lined with special ventilation cabinet, thick 6mm white surface SOLID PHENOLIC COMPOSITE LINER laminate chemical plate installed.
      D. table: the use of laboratory dedicated ceramic plate (high temperature 1200 degrees Celsius) or the use of 304, 316L stainless steel production. It has the advantages of corrosion resistance, antibacterial and antistatic.
      E. lighting: 30W fluorescent lamp
      F. handle: adopt SUS304 stainless steel sub light square handle.
      G. flow plate: using 6mm special thick compact air ventilation cabinet plate, installation position and angle to the exhaust distribution uniformity, no dead angle, under normal conditions, the diversion plate and middle and lower outlet exhaust volume proportion of each of about 50 - 10%, to ensure that the different proportion of gas can be effectively excluded, and the other a manually adjustable exhaust volume ratio design, can improve the middle and lower outlet exhaust volume ratio to 80% above, in order to adapt to the needs of different experiments.
      H. window: 5mm thick tempered glass. Internal use of pituitary balance device, can stay in the upper and lower positions.
      I. cabinet door open and high: 600 ~ 700mm.
      J. working face wind speed: 0.4 ~ 0.6m/s.
      K. exhaust air volume: 1080 ~ 1400m3/h.
      L. exhaust resistance: 5 ~ 12mmH2O.
      M. operating voltage: AC220V ~ 380V.
      N. motor power: 0.04 ~ 2.2kW (reference).
      O. electrical accessories: universal socket (220V/10A), fluorescent lamp, fan control.
      P. water: 1 group DN25. (configured as user requirements)
      Q. water: 1 groups of DN50. (configured as user requirements)
      R. outlet size: Phi 300mm.
      S. fan: the use of glass fiber reinforced plastic materials, acid and alkali resistance, anti-aging.
      T. duct: the use of glass fiber reinforced plastic materials, acid and alkali resistance, anti-aging.

      Main features:
      Safety
      The three baffle plates cause the harmful gas in the different height space to be discharged from different sections. The fume hood is used to discharge air in the fume hood at the speed of 0.5m/s of the operating surface wind speed to ensure that no residual gas exists. The ventilation efficiency is high, the exhaust air volume is 450-1600m3/h, and the noise is small. The utility model can provide more safe and comfortable test space for the experimenter.
      Intelligent control
      Ventilation ventilation fan ventilation, water, electricity, gas and ventilation integrated panel control, can be equipped with anti-corrosion, explosion-proof lighting, multi-function (three-phase, single-phase) socket. Gas pipeline and multiple water pipe interface. The utility model can meet the requirements of water, electricity and gas used in various experiments.
      economical efficiency
      Compared with the traditional bypass cabinet, in the air conditioning environment, can save about 50% of energy.

      Specification (standard type)

      Size 1200mm L*D*H 1500mm L*D*H 1800mm L*D*H
      External dimensions 1200*850*2350 1500*850*2350 1800*850*2350
      Internal dimensions 990*750*1205 1290*750*1205 1590*750*1205
      Lower cabinet size 1200*650*860 1500*650*860 1800*650*860
      Table Height 860 860 860
      Throttle opening height 650 650 650
      Recommended surface wind speed At the height of 60% of the opening of the air door, the fume hood shall use an average surface wind speed of not less than 0.5 m / S

      According to user requirements, design and manufacture of non-standard ventilation cabinet.

       
       
       